6313 pH or mV Controller/Transmitter

from $139.00

Brand: JENCO - pH Transmitter/Controller, Programmable, LCD Display

Features

  • Clear LCD displays pH or mV, with temperature and relay status simultaneously.

  • Automatic buffer recognition of US and NIST buffer sets. Calibration data is stored in memory and is ready for use on power-up.

  • Displays absolute and relative ORP.

  • Isolated and reversible 4-20 mA current output for pH or ORP allows it  to be used as a proportional output.

  • 2 programmable on/off relays: 2 for pH or ORP.

  • CE Approved

  • Password protection.

  • IP65

Meter and Electrode:
Quantity:
Add To Cart

Brand: JENCO - pH Transmitter/Controller, Programmable, LCD Display

Features

  • Clear LCD displays pH or mV, with temperature and relay status simultaneously.

  • Automatic buffer recognition of US and NIST buffer sets. Calibration data is stored in memory and is ready for use on power-up.

  • Displays absolute and relative ORP.

  • Isolated and reversible 4-20 mA current output for pH or ORP allows it  to be used as a proportional output.

  • 2 programmable on/off relays: 2 for pH or ORP.

  • CE Approved

  • Password protection.

  • IP65

Brand: JENCO - pH Transmitter/Controller, Programmable, LCD Display

Features

  • Clear LCD displays pH or mV, with temperature and relay status simultaneously.

  • Automatic buffer recognition of US and NIST buffer sets. Calibration data is stored in memory and is ready for use on power-up.

  • Displays absolute and relative ORP.

  • Isolated and reversible 4-20 mA current output for pH or ORP allows it  to be used as a proportional output.

  • 2 programmable on/off relays: 2 for pH or ORP.

  • CE Approved

  • Password protection.

  • IP65

 

 

pH and ORP Electrodes

IP-600-10 Industrial pH Electrode Flat Tip.png

IP-600-10 ELECTRODES

Industrial pH Electrode (Flat Tip) PPS housing with 3/4” threads front and rear and BNC connector, includes 5 m cable.

pH Range—0 to 14 pH

Operating Temperature 0 to 80 °C

Pressure Tolerance Range 1: 75C/170F = 100 psig

Pressure Tolerance Range 2: 81C/180F = 85 psig

Pressure Tolerance Range 3: 100C/212F =50 psig

Reference Type: Ag/AgCl, double Junction

Thread: 3/4″NPT

Connect Material——Sensor Material

PPS————————-Glass

Connector: BNC or other

Cable length: Call for additional info.

IR-500-8 Electrode_Probe.png

IR-500-8 ORP ELECTRODE

ORP Range: -2000 to 2000 mV

Operating Temperature: 0 to 80 °C

Pressure tolerance: 100 psig (at 25 °C)

Reference Type: AgCl, double Junction

Thread: 3/4″NPT

Sensor Material: Pt

Connector: BNC or other

Cable Length: 5 m or other



What is pH?

Acidic and alkaine/Basic are two extremes that describe substances, usually liquids or chemicals, just like hot and cold are two extremes that describe temperature. A substance that is neither acidic nor alkaline is neutral.

The pH scale measures how acidic or alkaline a substance is. The scale ranges from 0 to 14. A pH of 7 is neutral. A pH less than 7 is acidic, and a pH greater than 7 is basic. Pure water is neutral, with a pH of 7.0. When chemicals are mixed with water, the mixture can become some level of either acidic or alkaline. Vinegar and lemon juice are acidic substances, while laundry detergents and ammonia are alkaline.

What is ORP?

Oxidation reduction potential (ORP) is an important method for testing water quality. Oxidation occurs when a substance lacking electrons — known as an oxidizing agent — looks for electrons from other substances. On the other hand, substances that have extra electrons to donate are known as reducing agents.

ORP classifies substances as oxidizing or reducing agents and is measured in millivolts (mV) by an ORP meter. A high ORP reading indicates the presence of an oxidizing agent. A low reading indicates a reducing agent. Water pollution levels tend to increase with low ORP readings and decrease with high readings. Scientists consider the ORP of water as an important indicator of pollution levels. Safe drinking water, for example, is an oxidizing agent with an ORP range between +200 and +600 mV. Chlorinated pool water, on the other hand, should have a much higher ORP between +650 and +750 mV.

 
U900 Series Multi-Channel Industrial Controller
U900 Series Multi-Channel Industrial Controller
$0.00
Available for Backorder
D700 Series pH/ORP Controller
D700 Series pH/ORP Controller
$0.00
Available for Backorder
6309 POT pH/ORP and Temperature Analyzer
6309 POT pH/ORP and Temperature Analyzer
from $144.00